<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="en"><front><journal-meta><journal-id journal-id-type="publisher-id">gscience</journal-id><journal-title-group><journal-title xml:lang="en">Mining Science and Technology (Russia)</journal-title><trans-title-group xml:lang="ru"><trans-title>Горные науки и технологии</trans-title></trans-title-group></journal-title-group><issn pub-type="epub">2500-0632</issn><publisher><publisher-name>The National University of Science and Technology MISiIS (NUST MISIS)</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.17073/2500-0632-2023-01-72</article-id><article-id custom-type="elpub" pub-id-type="custom">gscience-474</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>POWER ENGINEERING, AUTOMATION, AND ENERGY PERFORMANCE</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>ЭНЕРГЕТИКА, АВТОМАТИЗАЦИЯ И ЭНЕРГОЭФФЕКТИВНОСТЬ</subject></subj-group></article-categories><title-group><article-title>Equivalent circuit for mine power distribution systems for the analysis of insulation leakage current</article-title><trans-title-group xml:lang="ru"><trans-title>Обоснование схемы замещения шахтной подземной электрической сети для анализа режимов утечки тока через изоляцию</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0001-7457-5702</contrib-id><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Пичуев</surname><given-names>А. В.</given-names></name><name name-style="western" xml:lang="en"><surname>Pichuev</surname><given-names>A. V.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Александр Вадимович Пичуев – кандидат технических наук, доцент кафедры энергетики и энергоэффективности горной промышленности.</p><p>Москва, Scopus ID 57209798580</p></bio><bio xml:lang="en"><p>Alexandr V. Pichuev – Cand. Sci. (Eng.), Associate Professor of the Department of Energy and Energy Efficiency of Mining Industry.</p><p>Moscow, Scopus ID 57209798580</p></bio><email xlink:type="simple">allexstone@mail.ru</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0002-6474-5349</contrib-id><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Петров</surname><given-names>В. Л.</given-names></name><name name-style="western" xml:lang="en"><surname>Petrov</surname><given-names>V. L.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Вадим Леонидович Петров – доктор технических наук, проректор, профессор кафедры энергетики и энергоэффективности промышленных предприятий.</p><p>Москва, Scopus ID 8919065900</p></bio><bio xml:lang="en"><p>Vadim L. Petrov – Dr. Sci. (Eng.), Vice-Rector, Professor of the Department of Energy and Energy Efficiency of Industrial Enterprises.</p><p>Moscow, Scopus ID 8919065900</p></bio><email xlink:type="simple">petrovv@misis.ru</email><xref ref-type="aff" rid="aff-1"/></contrib></contrib-group><aff-alternatives id="aff-1"><aff xml:lang="ru">Университет науки и технологий МИСИС<country>Россия</country></aff><aff xml:lang="en">University of Science and Technology MISIS<country>Russian Federation</country></aff></aff-alternatives><pub-date pub-type="collection"><year>2023</year></pub-date><pub-date pub-type="epub"><day>20</day><month>04</month><year>2023</year></pub-date><volume>8</volume><issue>1</issue><fpage>78</fpage><lpage>86</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Pichuev A.V., Petrov V.L., 2023</copyright-statement><copyright-year>2023</copyright-year><copyright-holder xml:lang="ru">Пичуев А.В., Петров В.Л.</copyright-holder><copyright-holder xml:lang="en">Pichuev A.V., Petrov V.L.</copyright-holder><license license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://mst.misis.ru/jour/article/view/474">https://mst.misis.ru/jour/article/view/474</self-uri><abstract><p>Successful mining businesses rely heavily on the safety and reliability of their mine power distribution systems. Mine power distribution systems are designed to withstand an aggressive environment with a range of hazards. The harsh operating conditions require improvement to personnel protection systems through the study and simulation of the electric network’s normal and emergency operations. The purpose of this study is to assess insulation leakage current using an equivalent circuit of a mine power distribution system. The simulation identified the key properties of the equivalent circuit which can model potential hazardous situations. We also selected the quantitative metrics and the equivalent circuit property ranges. In order to simulate the transients, we recommended using the time constants for the oscillation damping in circuits, the insulation phase resistance properties, and the absorption currents. This paper presents the equations to estimate these values. As an example, we considered the equivalent circuit of a mine power distribution system with an R-L filter in the residual current device line. The equivalent circuit helps analyze the current leakage when a person touches a live phase conductor accounting for low-frequency polarization in the phase insulation. The proposed approach to the simulation and analysis of the insulation current makes it possible to generate an equivalent circuit of the mine power distribution system to analyze phase voltage asymmetry, trip currents of residual current devices, low-frequency polarization of the insulation, and the leakage current effects on the human body.</p></abstract><trans-abstract xml:lang="ru"><p>Характеристики безопасности и надежности шахтных электротехнических комплексов и систем во многом обеспечивают успешность горных предприятий. Сложные технологические условия, особенно при ведении подземных горных работ, многообразие индивидуальных факторов определяют совокупность требований, которые предъявляются к подземным электрическим сетям горных предприятий. Все это определяет необходимость совершенствования систем защиты персонала на основе исследования характеристик сетей, моделирования режимов работы, в том числе аварийных. Основная цель исследований – обоснование схемы замещения шахтной подземной электрической сети путем синтеза ее структуры для последующего анализа режимов утечки тока через изоляцию. На основе методов математического моделирования дано обоснование параметров схемы замещения шахтной подземной электрической сети с учетом условий возникновения и развития аварийных и травмоопасных ситуаций. Определены количественные показатели и диапазоны изменения параметров элементов схемы замещения электрической сети. Для математического моделирования переходных процессов рекомендовано использование электромагнитных постоянных времени затухания колебаний в контурах, образованных параметрами фазных сопротивлений изоляции, а также абсорбционных составляющих токов утечки, и приведены соответствующие расчетные соотношения. В качестве примера приведена схема замещения шахтной подземной электрической сети с активно-индуктивным фильтром присоединения устройства защитного отключения, позволяющая выполнить анализ утечки тока при однополюсном прикосновении человека к токоведущей фазе, с учетом процесса низкочастотной поляризации в фазной изоляции. Предложенный методический подход к моделированию и анализу режимов утечки тока через изоляцию позволяет осуществить синтез схемы замещения подземной электрической сети для анализа несимметрии фазных напряжений, токов срабатывания устройств защитного отключения, процессов низкочастотной поляризации в изоляции, воздействия тока утечки на человека.</p></trans-abstract><kwd-group xml:lang="ru"><kwd>шахтная подземная электрическая сеть</kwd><kwd>режимы утечки тока</kwd><kwd>защитное отключение</kwd><kwd>параметры изоляции</kwd><kwd>источники ЭДС</kwd><kwd>электробезопасность</kwd></kwd-group><kwd-group xml:lang="en"><kwd>mine power distribution system</kwd><kwd>leakage current</kwd><kwd>residual current device</kwd><kwd>insulation properties</kwd><kwd>EMF sources</kwd><kwd>electrical safety</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Гладилин Л.В., Щуцкий В.И., Бацежев Ю. Г. и др. Электробезопасность в горнодобывающей промышленности. М.: Недра; 1977. 327 с.</mixed-citation><mixed-citation xml:lang="en">Gladilin L.V., Shchutsky V.I., Batsezhev Yu.G. et al. Electrical safety in the mining industry. Moscow: Nedra; 1977. 327 p. (In Russ.)</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Щуцкий В.И., Сидоров А.И., Ситчихин Ю.В. и др. Электробезопасность на открытых горных работах. М.: Недра; 1996.</mixed-citation><mixed-citation xml:lang="en">Shchutsky V.I., Sidorov A.I., Sitchikhin Yu.V. et al. Electrical safety in open–pit mining. Moscow: Nedra; 1996. (In Russ.)</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Пичуев А.В., Петуров В.И., Суворов И.Ф. Влияние нестационарных режимов на электробезопасность при эксплуатации электрооборудования горных предприятий. М.: Горная книга; 2011. 326 с.</mixed-citation><mixed-citation xml:lang="en">Pichuev A.V., Peturov V.I., Suvorov I.F. Effects of non-stationary modes on electrical safety of mining electrical equipment. Moscow: Gornaya kniga; 2011. 326 p. (In Russ.)</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Клюев Р.В., Босиков И.И., Гаврина О.А., Ляшенко В.И. Оценка эксплуатационной надежности электроснабжения развивающихся участков добычи руд на высокогорном руднике. Горные науки и технологии. 2021;6(3):211–220. https://doi.org/10.17073/2500-0632-2021-3-211-220</mixed-citation><mixed-citation xml:lang="en">Klyuev R.V., Bosikov I.I., Gavrina O.A., Lyashenko V.I. Assessment of operational reliability of power supply to developing ore mining areas at a high-altitude mine. Mining Science and Technology (Russia). 2021;6(3):211–220. (In Russ.) https://doi.org/10.17073/2500-0632-2021-3-211-220</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Ким К.Е. Исследование нестационарных режимов шахтных электрических сетей напряжением до 1000 В и их влияние на условия электробезопасности. [Дисс. канд. техн. наук] М.: МГИ; 1975.</mixed-citation><mixed-citation xml:lang="en">Kim K.E. Non-stationary modes in mine electrical networks up to 1,000 V and their impact on electrical safety. [Ph.D. Thesis] Moscow: Moscow Mining University; 1975. (In Russ.)</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Колосюк В.П. Защитное отключение рудничных электроустановок. М.: Недра; 1980. 334 с.</mixed-citation><mixed-citation xml:lang="en">Kolosyuk V.P. Emergency tripping in mine electrical installations. Moscow: Nedra; 1980. 334 p. (In Russ.)</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">Сидоров А. И., Петуров В.И., Пичуев А.В. и др. Обеспечение электробезопасности в системах электроснабжения. Успехи современного естествознания. 2010;(2):114. URL: https://natural-sciences.ru/ru/article/view?id=7752</mixed-citation><mixed-citation xml:lang="en">Sidorov A.I., Peturov V.I., Pichuev A.V. et al. Electrical safety of power supply systems. Advances in Current Natural Sciences. 2010;(2):114. URL: https://natural-sciences.ru/ru/article/view?id=7752 (In Russ.)</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">Петуров В.И. Способ измерения параметров изоляции фаз в сетях с изолированной нейтралью. Электробезопасность. 1998;(1):9–12.</mixed-citation><mixed-citation xml:lang="en">Peturov V.I. Method for measuring phase insulation properties in insulated neutral systems. Elektrobezopasnost. 1998;(1):9–12. (In Russ.)</mixed-citation></citation-alternatives></ref><ref id="cit9"><label>9</label><citation-alternatives><mixed-citation xml:lang="ru">Kano Murga J. Electricity. The danger of its use and protection of people from electric shock. MF. Per. GPNTB, “Instalador”. 1976;(106):75−78.</mixed-citation><mixed-citation xml:lang="en">Kano Murga J. Electricity. The danger of its use and protection of people from electric shock. MF. Per. GPNTB, “Instalador”. 1976;(106):75−78.</mixed-citation></citation-alternatives></ref><ref id="cit10"><label>10</label><citation-alternatives><mixed-citation xml:lang="ru">Pouvel I. Problems de protection dans les reseaux miniers. Revue de l’industrie minerale. 1983;25(7). (In French)</mixed-citation><mixed-citation xml:lang="en">Pouvel I. Problems de protection dans les reseaux miniers. Revue de l’industrie minerale. 1983;25(7). (In French)</mixed-citation></citation-alternatives></ref><ref id="cit11"><label>11</label><citation-alternatives><mixed-citation xml:lang="ru">Kupfer J., Bastek R., Eggert S. Grenzwerte zur Vermeidung von unfallen durch electrischen strom min tödlichem Ausgang. Zeitschrift für die Gesamte Hygiene. 1981;27(1):9−12.</mixed-citation><mixed-citation xml:lang="en">Kupfer J., Bastek R., Eggert S. Grenzwerte zur Vermeidung von unfallen durch electrischen strom min tödlichem Ausgang. Zeitschrift für die Gesamte Hygiene. 1981;27(1):9−12. (In German)</mixed-citation></citation-alternatives></ref><ref id="cit12"><label>12</label><citation-alternatives><mixed-citation xml:lang="ru">Суворов И.Ф. Комплексные системы обеспечения условий электробезопасности при эксплуатации электроустановок до 1000 В. Чита: ЧитГУ; 2005. 328 с.</mixed-citation><mixed-citation xml:lang="en">Suvorov I. F. Integrated electrical safety systems for electrical installations up to 1000 V. Chita: Chita State University; 2005. 328 p. (In Russ.)</mixed-citation></citation-alternatives></ref><ref id="cit13"><label>13</label><citation-alternatives><mixed-citation xml:lang="ru">Хусаинов Ш.Н., Сидоров А.И., Хусаинова Н.А. Улучшенный метод определения проводимостей изоляции участка сети, содержащего линию с отпайкой, по результатам измерения режимных параметров. Вестник ЮУрГУ. Серия «Энергетика». 2002;(7):24–29.</mixed-citation><mixed-citation xml:lang="en">Khusainov Sh.N., Sidorov A.I., Khusainova N.A. Improved method for insulation conductivity estimation of a grid segment with a branch line from the electric parameter measurements. Bulletin of South Ural State University. Series: Power Engineering. 2002;(7):24–29. (In Russ.)</mixed-citation></citation-alternatives></ref><ref id="cit14"><label>14</label><citation-alternatives><mixed-citation xml:lang="ru">Пичуев А. В. Параметрические зависимости сопротивления изоляции рудничных участковых электрических сетей. Горный информационно-аналитический бюллетень. 2011;(4):398–400.</mixed-citation><mixed-citation xml:lang="en">Pichuev A.V. Parametric relationships for the insulation resistance of mine electrical networks. Mining Informational and Analytical Bulletin. 2011;(4):398–400. (In Russ.)</mixed-citation></citation-alternatives></ref><ref id="cit15"><label>15</label><citation-alternatives><mixed-citation xml:lang="ru">Цапенко Е.Ф. Резонансные перенапряжения в шахтных сетях вследствие применения аппаратов защиты типа УАКИ, АЗАК, АЗШ, АЗУР. Горный информационно-аналитический бюллетень. 2000;(3):106–109.</mixed-citation><mixed-citation xml:lang="en">Tsapenko E.F. Resonant overvoltages in mine networks caused by the use of UAKI, AZAK, AZSh, AZUR RCP Devices. Mining Informational and Analytical Bulletin. 2000;(3):106–109. (In Russ.)</mixed-citation></citation-alternatives></ref><ref id="cit16"><label>16</label><citation-alternatives><mixed-citation xml:lang="ru">Цапенко Е.Ф. Состояние защиты от токов утечки на землю в шахтных сетях напряжением до 1200 В. Горный информационно-аналитический бюллетень. 2003;(6):155–156.</mixed-citation><mixed-citation xml:lang="en">Tsapenko E.F. Leackage current protection monitoring in mine networks up to 1,200 V. Mining Informational and Analytical Bulletin. 2003;(6):155–156. (In Russ.)</mixed-citation></citation-alternatives></ref><ref id="cit17"><label>17</label><citation-alternatives><mixed-citation xml:lang="ru">Пичуев А.В. Режимы несимметричной утечки тока через изоляцию рудничной участковой электрической сети. Электробезопасность. 2011;(2):28−33.</mixed-citation><mixed-citation xml:lang="en">Pichuev A.V. Unsymmetrical current leakage through the insulation in mine electrical networks. Elektrobezopasnost. 2011;(2):28–33. (In Russ.)</mixed-citation></citation-alternatives></ref><ref id="cit18"><label>18</label><citation-alternatives><mixed-citation xml:lang="ru">Abderrezak H., Mizane A. Hybrid model for insulation active component control in an isolated neutral electrical network. In: Proceedings of the 2012 International Conference on Industrial Engineering and Operations Management. Istanbul, Turkey, July 3–6, 2012. Pp. 1961−1970. URL: https://ieomsociety.org/ieom2012/pdfs/466.pdf</mixed-citation><mixed-citation xml:lang="en">Abderrezak H., Mizane A. Hybrid model for insulation active component control in an isolated neutral electrical network. In: Proceedings of the 2012 International Conference on Industrial Engineering and Operations Management. Istanbul, Turkey, July 3–6, 2012. Pp. 1961−1970. URL: https://ieomsociety.org/ieom2012/pdfs/466.pdf</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
